Educational information for healthcare professionals and patients
Delp Medtech
Ultrasound tomography

Three acoustic views, one volumetric picture

TriAD technology combines reflected echoes with transmitted sound-speed and attenuation measurements to create complementary views of breast structure and tissue properties.

Delp Medtech clinical imaging workstation in a modern diagnostic environment
Reflection, sound speed, and attenuation are acquired around the breast and reconstructed for clinical review.
Trifecta of sound

Complementary acoustic information

A uniform circular transducer arrangement emits and receives ultrasound signals from many positions. The resulting reflection and transmission data are reconstructed into coronal image stacks that trained readers can compare with other breast imaging studies.

01

Reflection

Backscattered echoes depict boundaries and structural detail within breast tissue.

02

Sound speed

Transmission timing measures how the speed of sound changes as signals pass through tissue.

03

Attenuation

Signal reduction through tissue provides another quantitative acoustic property for image reconstruction.

Delp Medtech clinician reviewing reconstructed medical images
Acquisition principles

A circular scan from multiple angles

Transducer elements operate in sequence around the breast. As the ring advances, the system collects thin sections that are assembled into volumetric datasets.

  • Signals are emitted and received around a 360-degree array
  • Acquisition progresses from the nipple region toward the chest wall
  • Reflection echoes and transmitted signals are captured during the same scan
  • Reconstruction presents coronal cross-sections in volumetric stacks

These technical descriptions explain the imaging process; they do not establish suitability for an individual patient.

How the data becomes an image

From signal to review

The system follows a structured acquisition and reconstruction process designed to preserve several types of acoustic information for interpretation.

Position

The breast is positioned within the imaging aperture for automated circular acquisition.

Acquire

Elements transmit and receive signals while the array advances in small increments.

Reconstruct

Algorithms convert reflection, sound-speed, and attenuation measurements into image data.

Interpret

Trained readers review complementary stacks alongside mammography and relevant history.

Image sequences

Four volumetric stacks

Different reconstructions emphasise different aspects of anatomy and tissue properties. They are designed for side-by-side interpretation rather than as independent diagnoses.

Structural output

Reflection

Displays tissue structure from backscattered ultrasound signals.

Quantitative output

Sound speed

Maps measured changes in acoustic propagation speed through breast tissue.

Combined output

Wafer

Combines sound-speed and reflection information to reduce the visual prominence of fat and accentuate remaining tissue.

Combined output

Stiffness fusion

Combines sound-speed and attenuation information to display relative differences in tissue stiffness.

Transducer design

System characteristics

The circular assembly is engineered to collect dense acoustic data from multiple paths. Specifications below summarise the source material and should be confirmed against current product documentation.

Close view of precision diagnostic equipment representing Delp Medtech transducer engineering
Data resolution14-bit
Transducer elements2,048
Channels512
Ring diameter22 cm
Acquisition increment2 mm
Beam overlap0.5 mm
Image resolution0.7 mm
Beam thickness2.5 mm

Specifications can change as systems and documentation are updated. Clinical teams should use applicable labelling, training, and technical materials.

Common questions

Technology in context

These answers provide a general explanation and do not replace clinical training or individual medical advice.

What does TriAD technology measure?

It collects reflected ultrasound echoes and transmitted signals used to reconstruct reflection, sound-speed, and attenuation information.

Why collect signals from a circular array?

Acquiring information around the breast provides multiple acoustic paths that can be combined during tomographic reconstruction.

What is a coronal image?

It is a cross-sectional view presented as though looking from the front through successive layers. Multiple slices form a volumetric stack.

What is the difference between reflection and transmission?

Reflection describes echoes returning from tissue boundaries. Transmission measurements examine how signals change while passing through tissue.

Does the technology replace mammography?

No. This imaging approach is intended for use alongside mammography in an appropriate clinical context.

Do image properties provide a diagnosis by themselves?

No. Images require interpretation by qualified professionals alongside other studies, history, risk, and clinical findings.