Reflection
Backscattered echoes depict boundaries and structural detail within breast tissue.
TriAD technology combines reflected echoes with transmitted sound-speed and attenuation measurements to create complementary views of breast structure and tissue properties.
A uniform circular transducer arrangement emits and receives ultrasound signals from many positions. The resulting reflection and transmission data are reconstructed into coronal image stacks that trained readers can compare with other breast imaging studies.
Backscattered echoes depict boundaries and structural detail within breast tissue.
Transmission timing measures how the speed of sound changes as signals pass through tissue.
Signal reduction through tissue provides another quantitative acoustic property for image reconstruction.

Transducer elements operate in sequence around the breast. As the ring advances, the system collects thin sections that are assembled into volumetric datasets.
These technical descriptions explain the imaging process; they do not establish suitability for an individual patient.
The system follows a structured acquisition and reconstruction process designed to preserve several types of acoustic information for interpretation.
The breast is positioned within the imaging aperture for automated circular acquisition.
Elements transmit and receive signals while the array advances in small increments.
Algorithms convert reflection, sound-speed, and attenuation measurements into image data.
Trained readers review complementary stacks alongside mammography and relevant history.
Different reconstructions emphasise different aspects of anatomy and tissue properties. They are designed for side-by-side interpretation rather than as independent diagnoses.
Displays tissue structure from backscattered ultrasound signals.
Maps measured changes in acoustic propagation speed through breast tissue.
Combines sound-speed and reflection information to reduce the visual prominence of fat and accentuate remaining tissue.
Combines sound-speed and attenuation information to display relative differences in tissue stiffness.
The circular assembly is engineered to collect dense acoustic data from multiple paths. Specifications below summarise the source material and should be confirmed against current product documentation.
Specifications can change as systems and documentation are updated. Clinical teams should use applicable labelling, training, and technical materials.
These answers provide a general explanation and do not replace clinical training or individual medical advice.
It collects reflected ultrasound echoes and transmitted signals used to reconstruct reflection, sound-speed, and attenuation information.
Acquiring information around the breast provides multiple acoustic paths that can be combined during tomographic reconstruction.
It is a cross-sectional view presented as though looking from the front through successive layers. Multiple slices form a volumetric stack.
Reflection describes echoes returning from tissue boundaries. Transmission measurements examine how signals change while passing through tissue.
No. This imaging approach is intended for use alongside mammography in an appropriate clinical context.
No. Images require interpretation by qualified professionals alongside other studies, history, risk, and clinical findings.
Clinical teams can consult the science section, clinical monograph, and case studies, then request further information where needed.
Contact Delp Medtech for general technical resources or professional information.